Aux Solenoid Valve; Specifications - Kubota KX080-4 Workshop Manual

Hide thumbs Also See for KX080-4:
Table of Contents

Advertisement

KX080-4, WSM

[2] AUX SOLENOID VALVE

(1) Specifications

Proportional Control Solenoid Valve
This valve is an electromagnetic solenoid valve. Normally a solenoid valve is turned off and on via 12V battery
voltage, but this valve is controlled via pulsed signals from the computer built into the ECU and the meter panel.
(Duty Control)
Item
Max operating pressure
(input pressure)
Allowable back pressure
(pressure T)
Maximum proportional valve
operating flow volume
(input flow volume)
Drain volume when solenoid off
Waterproof Standard
Vibration Proof Standard
Hydraulic Oil Grade
Hydraulic Oil Contamination
Level
Electrical Specifications
Secondary pressure control
range
(1) P port
(2) T port
(3) A1 Port (Hi)
(4) A2 Port (Low)
3-M57
HYDRAULIC SYSTEM
Specifications
3.9 MPa
2
40 kgf/cm
570 psi
1.0 MPa
2
10 kgf/cm
100 psi
15.6 L/min (4.1 GPM)
0.4 L/min ≥
[at 20 cST, port P pressure =
2
4.9 MPa (50 kgf/cm
, 710 psi)]
JIS D 0203 S2 equivalent
JIS D 1601–1995
ISO VG32 to 68 equivalent
NAS Class 10 or less
Rated Amperage: 1600 mA
Coil resistance: 3.2 ± 0.5 Ω
[at 20 deg C (68 deg F)]
0 to 2.7 MPa
2
0 to 27 kgf/cm
0 to 390 psi
(a) Secondary Pressure (MPa)
(b) Input Amperage (mA)
RY9212148HYM0025US0
KiSC issued 08, 2015 A