Kubota KX080-4 Workshop Manual page 399

Hide thumbs Also See for KX080-4:
Table of Contents

Advertisement

KX080-4, WSM
[B] Inspecting each Device Visually and Physically
1. Causes when a break in wiring
[Test Conditions]
1. Key switch : OFF
2. The 2-speed solenoid connector disconnected.
3. The 2-speed switch connector disconnected.
4. There is a break somewhere in the wiring.
Pull on the harness and make sure the connector/harness does
not come off. (pull with a max of 3 kgf (30 N, 7 lbf) of force) If it
comes off, plug the connector back in securely and check the
2-speed solenoid and the 2-speed switch in the tester mode.
(a) 2-Speed Solenoid Connector
2. Causes when a short
[Test Conditions]
1. Key switch : OFF
2. The wiring of the 2-speed solenoid connector and/or the
2-speed switch connector are pinched against or touching the
body
If the insulation is damaged, repair it properly and check the
2-speed solenoid and the 2-speed switch again in the tester
mode.
4-S68
ELECTRICAL SYSTEM
(b) 2-Speed Switch Connector
RY9212148ELS0098US0
RY9212148ELS0099US0
KiSC issued 08, 2015 A