Table 2-2: Default Jumper Settings (Cont'd)
Number
Ref. Des.
26
J113
27
J88
28
J38
29
J153

Switches

Table 2-3: Default Switch Settings
Number
For this DIP switch, in relation
Note:
to the arrow, moving the switch
30
toward the label ON is a 0. DIP switch
labels 1 through 4 are equivalent to
mode pins 0 through 3.
For this DIP switch, in relation
Note:
31
to the arrow, moving the switch
toward the label ON is a 0. 1 through
5 are tied to MSP430 U41 GPIO[1:5].
32
33
ZCU106 Board User Guide
UG1244 (v1.0) March 28, 2018
Function
Device/host or OTG select
• 1-2: Device or host
• 2-3: OTG
ARM trace VTREF
• 1-2: 3.3V
• Open: 0V
ARM trace power
• 1-2: 3.3V
• Open: 0V
Power inhibit
• Open: Rails power on normally
• 1-2: All rails (except UTIL) OFF
Ref. Des.
Switch PS_MODE select
SW6
(ON = pull down, OFF = pull up)
1: PS_MODE0
2: PS_MODE1
3: PS_MODE2
4: PS_MODE3
MSP430 GPIO
1: SW0
SW8
2: SW1
3: SW2
4: SW3
5: SW4
SW13
GPIO
SW1
Main power switch
www.xilinx.com
Chapter 2: Board Setup and Configuration
Default
1-2
Open
1-2
1-2
Function
Schematic Page
57
60
60
65
Schematic
Default
Page
On
12
On
On
On
Off
Off
42
Off
Off
Off
All Off
59
Off
65
19