4.3
System
4.3.2

Display

4.3.2.1 Parameter overview

Functional block:
Number
Name
135.1
Mode error display

4.3.2.2 Description of the Parameters

135.1
Mode Error Display
15 ... 0
23 ... 16
31 ... 25
90
Parameter manual b maXX BM3000
Document no.: 5.12001.07
of 820
FbDisplay [135]
Type
Min
UDINT
0
Bit
Value
Reserved
0
Only errors (with a response set in the parameters) are displayed:
the error-LED H14 (axis 1) or H24 (axis 2) is on in case of error.
If only warnings or errors without a response set in the parameters
are triggered, the error-LED flashes
1
All errors and warnings are displayed; the error-LED is on perma-
nently in case of error or warning.
24
Activation of LED Power On (H12 (axis 1) or H22 (axis 2), if power
on
0
LED is on permanently
1
LED flashes (life signs)
Reserved
Max
Default Value Unit
0xFFFFFFFF 0x1010000
Meaning
Factor
1:1
X