Communication Via Ethercat - Baumuller b maXX BM3000 Operating Manual

Parameter
Hide thumbs Also See for b maXX BM3000:
Table of Contents

Advertisement

2.5

Communication via EtherCAT

2.5
Communication via EtherCAT
BM2500 with EtherCAT
BM25XX-XXX1-...
For the communication via EtherCAT the following is required:
m EtherCAT Master
m Controller
m Power supply unit
m Engineering Framework
n Leave the base address on the EtherCAT Master unchanged (192.168.1.1).
h Set the desired IP address on the BM2500 controller (here 192.168.1.2).
h Set a fixed IP address on the PC or use a second network card:
Figure 1:
20
Parameter manual b maXX BM3000
Document no.: 5.12001.07
of 820
®
CoE profile with the following type code is required:
You will find further information about this in the b maXX BM2500, 5.16020 Operating
Manual, Art. No. 441838. and in the EtherCAT
440084).
System Control  Network Connections  LAN Connection  Properties 
 Internet Protocol (TCP/IP)  Properties  Assign fixed IP address 
from the same address space (here, e.g. 192.168.1.254).
Setting fixed IP addresses
BMC-M-ECT-02
BMC-M-PLC-02
BMC-M-PSB-01
ProMaster
®
, 5.10030 Application Manual, Art. No.