4.5
Management
m Set Standard Values for an Individual Data Set
This data set command resets all parameter of the target data set (the data set parameter
only) to the default values.
Possible error messages:

4.5.2.10 Changeover to Data Set 1 to 7

Changing data sets is possible both with the device inhibited and with the controller run-
ning.
Due to the mechanical inertia of the systems being controlled and the high sampling rate
of the drive, a changeover free of mechanical shocks can be assumed.
NOTE!
No consideration can be given to inconsistent set values and monitored values during
the changeover of data sets. During the changeover, the possibility cannot be ruled
out that, e.g., a monitored value in the new data set is smaller than the associated
instantaneous actual value of the previously active data set. In this case a monitoring
function which, e.g., initiates a pulse inhibit could respond.
The data set changeover is effected by writing to the Parameter
Number.
Before the changeover, a check is made to ensure that the data set has been created.

4.5.2.11 Overview of the Data Set Management Commands

Reset the Data Set Management
System
Write all parameters from the created
data sets into Flash memory
Read Flash completely
Clear Flash completely
Set standard values for the target
data set
Set standard values for all writable
parameters
368
Parameter manual b maXX BM3000
Document no.: 5.12001.07
of 820
n Device is not inhibited
Z105.1–
Data Set Management
Command
Z105.6–
Z105.8–
Value
Source data set
0
1
2
3
4
5
Baumüller Nürnberg GmbH
Active Data Set
Z105.9–
Target Data Set
Data set which is to
be set to standard
values