Description of the Software Modules and Parameters

4.8.3.11 Homing Methods 5 and 6 (neg. zero point changeover switch)

Homing occurs in the direction of the negative zero point changeover switch, which
means the switch may be anywhere in the traversing range and is continuously active
from the switch point in negative direction. The initial direction of travel depends on the
switching mode and applied method.
The home position is the first zero pulse or zero angle on the left or right of the switch.
Figure 196:
Homing methods 5 and 6
Parameter manual b maXX BM3000
Document no.: 5.12001.07
4
589
of 820