4.5
Management

4.5.2.13 Description of the Parameters

105.1
Command
Commands for data set management:
Value
105.2
Status
Displays the status of the data set management system.
While the command is being processed, the value 1 (RC_BUSY) is displayed.
After the command has completed the value 3, for RC_DONE, is displayed or possibly
the code for any error that occurred during processing.
List of the most frequent status messages (RC codes):
Value
370
Parameter manual b maXX BM3000
Document no.: 5.12001.07
of 820
Meaning
0
Resets the DSM; the message list is deleted
1
Saves the parameter set in Flash
2
Loads the parameter set from Flash
3
Deletes the parameter set in Flash
4
Set all parameters in the target data set to the default value
5
Sets all savable parameters to the default value
6
Create Data Set X (target data set)
7
Delete Data Set X (target data set)
8
Copy the source data set to the target data set
9
Read the source data set from Flash again
10
Reserved
RC Code
0
RC_NO_ERROR
1
RC_BUSY
3
RC_DONE
1400
RC_ERR_DSV
Meaning
No command executed yet or else Reset
command executed.
A command is being executed.
A command has completed successfully
Error while loading or saving the parame-
ter set (see Message parameters)
Baumüller Nürnberg GmbH