3.4
Preparations
3.4.2

Communication via EtherCAT

BM3000 with EtherCAT
BM3XXX-XXXX-XXXXX[-X]-1XXXX[-S0X]-XX[-XX][-EXX][-#XX]
For the communication via EtherCAT the following is required:
m EtherCAT Master
m Controller
m Power supply unit
m Engineering Framework
n Leave the base address on the EtherCAT Master unchanged (192.168.1.1).
n Set the desired IP address on the BM3000 controller (here 192.168.1.2).
n Set a fixed IP address on the PC or use a second network card:
Figure 34:
n Start ProMaster.
n Select b maXX controller PLC with EtherCAT Master from the catalog.
n Select b maXX 3300 Drive from the catalog.
n Open/activate the Workspace window.
52
Parameter manual b maXX BM3000
Document no.: 5.12001.07
of 820
®
with the following type code is required:
You will find further information about this in the b maXX BM3000, 5.11018 Operating
Manual, Art. No. 441839.
System Control  Network Connections  LAN Connection  Properties 
 Internet Protocol (TCP/IP)  Properties  Assign fixed IP address 
from the same address space (here, e.g. 192.168.1.254).
Setting fixed IP addresses
BMC-M-ECT-02
BMC-M-PLC-02
BMC-M-PSB-01
ProMaster
Baumüller Nürnberg GmbH