The output of the field weakening controller is the set value of the flux controller at asyn-
chronous machines. The flux controller is a simple PI-controller with proportional gain Kp,
integral time Tn and limitation. The Isd-set value is at the output of the flux controller.
The actual flux value is calculated from an asynchronous machine value. If the Kp of the
flux controller is set to 0, the inverse of the Imr-flux-characteristic is set for the Isd-set val-
ue.

4.7.6.1 ProDrive Flux controller

Figure 172:

4.7.6.2 Parameter Overview of the Flux Controller

Functional blocks:
Number
Name
146.10
Kp flux controller
146.11
Tn flux controller
146.12
Limit magnetizing current
146.15
Actual flux current
146.18
Integral term flux controller
518
Parameter manual b maXX BM3000
Document no.: 5.12001.07
of 820
ProDrive Flux controller
FbAsynchronmaschine [146]
Type
Min
Max
FLOAT
0
1e9
FLOAT
0
10000
FLOAT
0
1e9
FLOAT
-1e9
1e9
FLOAT
-1e9
1e9
Default Value Unit
Factor
0
1/s
1:1
1000
ms
1:1
10
A
1:1
0
A
1:1
0
A
1:1
Baumüller Nürnberg GmbH
X
X
X
X
X