Description Of The Two-Level Controller Parameter With Relative And Absolute Thresholds - Baumuller b maXX BM3000 Operating Manual

Parameter
Hide thumbs Also See for b maXX BM3000:
Table of Contents

Advertisement

4.7
Controllers
The absolute two-level controller switches on, if the following is valid:
151.15
Upper threshold absolute UDINT
If the data type of the parameter selected with
WORD or DWORD, then this parameter forces the upper absolute switching threshold.
The absolute two-level controller switches off, if the following is valid:

4.7.5.9 Description of the Two-level Controller Parameter with relative and absolute Thresholds

152.1
Mode
Configuration of the relative two-level controller
15 ... 3
152.2
Status
State of the relative two-level controller
514
Parameter manual b maXX BM3000
Document no.: 5.12001.07
of 820
Parameter number actual value  lower absolute switching threshold
Parameter number actual value  upper absolute switching threshold
Bit
Meaning
0
0: Comparison actual value to absolute thresholds inactive
1: Comparison actual value to absolute thresholds active
1
0: Comparison actual value to relative thresholds inactive
1: Comparison actual value to relative thresholds active
2
0: No absolute-value generation at actual value (comparison signed)
1: Absolute-value generation at actual value (symmetrical monitoring)
Reserved
Bit
Meaning
0
Status indication of the entire two-level controller
0: Output inactive
1: Output active
1
Status indication of the absolute two-level controller
0: Output absolute two-level controller inactive
1: Output absolute two-level controller active
Z151.3–
is INT, DINT, UINT, UDINT,
Baumüller Nürnberg GmbH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B maxx bm2500

Table of Contents