Error Detection; Error Handling; Error Reset - Baumuller b maXX BM3000 Operating Manual

Parameter
Hide thumbs Also See for b maXX BM3000:
Table of Contents

Advertisement

5.3

Error detection

5.3
Error detection
The illumination of the red LEDs H14 (axis 1) and H24 (axis 2) on the front of the housing
signals the occurrence of a error status.
A max. of 3 LEDs
Essentially, the lowest red LEDs H14 and H24 "Error" are of significance here.
are illuminated.
NOTE!
In case of warnings or errors without error reactions, the LEDs H14 or H24 blink "Er-
ror". Only error messages with error reaction will be signalized by constant lighting
up.
5.4

Error handling

Error messages, which can also be considered error lists, are the basis of the error han-
dling.
NOTE!
The device is shipped with predefined error reactions. With regard to the error mes-
sages identified with "depending on the setting" in the "Reaction" column, the de-
vice's error reaction can be adjusted. Errors that, due to safety reasons, have an
immediate pulse inhibit as a consequence, may not be changed.
5.4.1

Error reset

If the red error LED is illuminated, at least one error is present.
Error reset cause all error messages to be reset. Individual resetting of errors is not pos-
sible. A reset causes deletion of the errors, if deletion was possible on account of the error
circumstances.
There are two methods of resetting an error:
m By means of write access to the control word
m Via a digital input
For further information on the subject of error reset, see "Instruction Manual b maXX
3000".
746
Parameter manual b maXX BM3000
Document no.: 5.12001.07
of 820
Baumüller Nürnberg GmbH