Prodrive Analog Input; Parameter Overview; Description Of The Parameters - Baumuller b maXX BM3000 Operating Manual

Parameter
Hide thumbs Also See for b maXX BM3000:
Table of Contents

Advertisement

4.4
Configuration

4.4.12.2 ProDrive analog input

Figure 99:

4.4.12.3 Parameter overview

Functional block:
Number
Name
144.1
Time constant PT1 analog
input 1
144.2
Scaling factor analog input 1 FLOAT
144.3
Offset analog input 1
144.4
Treshold analog input 1
144.5
Value analog input 1
144.6
Target number analog input
1
144.20
Time slot analog inputs

4.4.12.4 Description of the Parameters

144.1
Time constant PT
Time constant of the PT
228
Parameter manual b maXX BM3000
Document no.: 5.12001.07
of 820

ProDrive analog input

FbAnalogInput [144]
Type
Min
Max
FLOAT
0
0.060
-1000000000
1000000000
FLOAT
-10
10
FLOAT
-10
10
FLOAT
-23
23
UDINT
0
0xFFFFFFFF 0
UINT
0
3
analog input 1
1
filter for smoothing the analog input signal on Channel 1
1
Default Value Unit
Factor
0.001
ms
1:1000
1
1/V
1:1
0
V
1:1
0
V
1:1
0
V
1:1
1:1
0
1/2/3
1:1
Baumüller Nürnberg GmbH
X
X
X
X
X
X
X

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B maxx bm2500