4.4
Configuration

4.4.12 Analog Inputs

4.4.12.1 Description of the Analog Inputs

The b maXX 3300 functionality for reading the analog inputs is shown in the diagram be-
low.
Figure 95:
K
S1
PGain:
Max:
Remarks concerning the amplitude of the input signal:
10 V corresponds to 100%
The hardware is designed so that the analog inputs can cope with a signal level of 12.3
V. These remaining, unexploited 2.3 V are kept in reserve. Regarding the size of the 12-
bit input register, the following applies:
-12.3 V...+12.3 V corresponds to 0...4095
226
Parameter manual b maXX BM3000
Document no.: 5.12001.07
of 820
Structure of the analog inputs on the b maXX 3000
,K
:
Scaling factors which can be set by the user.
S2
(Parameter Z144.2–)
Conversion factors 1 and 2
Maximum value of the target parameter
Baumüller Nürnberg GmbH