Description of the Software Modules and Parameters

4.11.2 Position Error monitoring

The position error is the difference between the position set value and the actual position.
It can be monitored statically or dynamically.
The dynamic position error limit will become effective as soon as a new position set value
is available for each sampling time of the position controller.
The static position error limit becomes effective when the position controller either does
not receive a new position set value or it continues to receive the same position set value
repeatedly.
Two separate limits (thresholds) are available for position error monitoring. The following
property settings may be entered for each limit:
Two bits are assigned to each threshold in the Parameter
position error exceeds one of the two thresholds, the bit "Position Error Limit Exceeded"
will be set in the
error time that was entered, another bit is set in the Status and the error
will be reported.
If the position error falls below the threshold setting, the status bit "Position error limit ex-
ceeded" will be deleted again.
The cycle of the position error monitoring is 1 ms.

4.11.2.1 Parameter overview

Functional block:
For Parameter 47.55, see
Number
Name
143.1
Status
143.2
Mode 1
143.3
Position error limit 1
143.4
Position error monitoring
Time 1
143.5
Mode 2
143.6
Position error limit 2
143.7
Position error monitoring
time 2
m Size of the window (position error limit)
m Response time (position error time)
m Type of monitoring - static, dynamic or both (see Mode 1
Z143.5–)
Z143.1–
207 Position error limit 1 exceeded or 
208 Position error limit 2 exceeded
FbMonitoring [143]
Type
Min
WORD
0
UINT
0
UDINT
0
UINT
0
UINT
0
UDINT
0
UINT
0
Status. If the position error remains longer than the position
ZCurrent Controller–
from page 469
Max
Default Value Unit
0xFFFF
0
2
0
0xFFFFFFFF 0xFFFFFFFF
0xFFFF
0xFFFF
2
0
0xFFFFFFFF 0xFFFFFFFF
0xFFFF
0xFFFF
Parameter manual b maXX BM3000
Document no.: 5.12001.07
Z143.2–
and Mode 2
Z143.1–
Status. If the actual
Factor
1:1
X
1:1
X
1:1
X
ms
1:1
X
1:1
X
1:1
X
ms
1:1
X
4
719
of 820

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B maxx bm2500

Table of Contents