B) Dependent Of External Total Current Limit (Field Weakening Is Not Assumed); Torque Current Limit "Lsqlim" At "Standard Load Mode" Of The Asynchronous Motor; A) Dependent Of The Field Current (External Total Current Limit Is Not Assumed).  B) Dependent Of External Total Current Limit (Field Weakening Is Not Assumed); A) Dependent Of The Field Current (External Total Current Limit Is Not Assumed) - Baumuller b maXX BM3000 Operating Manual

Parameter
Hide thumbs Also See for b maXX BM3000:
Table of Contents

Advertisement

Description of the Software Modules and Parameters
Isq
isq 100
loading
isqMax
[%]
19.8
100%
N
isq
[A]
isqMax 19.8
N
isd-set
[A]
Isd-nom
0
a)
0
N 107.7
Figure 153:
IsqLim
-1
n [min ]
N
2
2
=
-
LT-Imax-act
isd-set
IsqLim
-1
n [min ]
N
-1
n [min ]
N

Torque current limit "lsqLim" at "Standard load mode" of the asynchronous motor

bit 1 = 0, bit 3 = 0). 
a) Dependent of the field current (external total current limit is not assumed). 

b) Dependent of external total current limit (field weakening is not assumed).

Isq
loading
[%]
100%
isq
[A]
IsqLim
i drive
[A]
LT-Imax
19.6
b)
Parameter manual b maXX BM3000
Document no.: 5.12001.07
4
5000_0353_rev01_int
IsqLim
isqMax 19.8
LT-Imax-act 19.5
external
drive current limit
(138.1
473
of 820
t
t
t

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B maxx bm2500

Table of Contents