4.4
Configuration
Conversion between Factor Group parameters and controller parameters:
Position window P179.11
(0x6067)
Target position P179.12
(0x607A)
Home offset P179.13
(0x607C)
Minimal software position limit
P179.14
(0x607D.01)
Maximal software position limit
P179.15
(0x607D.02)
Position actual value P179.10
(0x6064)
Touch probe 1 pos. value P179.16
(0x60BA)
Touch probe 1 neg. value P179.17
(0x60BB)
Touch probe 2 pos. value P179.18
(0x60BC)
Touch probe 2 neg. value P179.19
(0x60BD)
Position error actual value P179.20
(0x60F4)
Figure 122:
320
Parameter manual b maXX BM3000
Document no.: 5.12001.07
of 820
Position weighting unsigned
X
Position weighting signed
X
Position weighting unsigned
X
Position weighting signed
X
Position weighting signed
X
1/ Position weighting unsigned
X
1/
Position weighting
unsigned
X
1/
Position weighting
unsigned
X

Factor Group effect of position weighting

Positioning positioning window (P121.5)
Positioning relative target position (P118.16)
Cyclic position set value specification
target position (P136.3)
Home position (P120.3)
Negative software limit switch (P121.3)
Positive software limit switch (P121.4)
Positioning position actual value (P121.9)
Touch probe revolutions+angle
(selection with P124.30
from P124.5 ... 124.16 or 124.18)
Position error rev+angle (P18.60)