Analog Outputs; Description Of The Analog Outputs; Prodrive Analog Outputs - Baumuller b maXX BM3000 Operating Manual

Parameter
Hide thumbs Also See for b maXX BM3000:
Table of Contents

Advertisement

4.4
Configuration

4.4.13 Analog Outputs

4.4.13.1 Description of the Analog Outputs

Using the analog outputs, any drive parameters such as, e.g., actual current, actual
speed or position errors can be output.
Both floating point and integer parameters can be output.
A total of two channels are available for the analog outputs. Thus a maximum of 2 drive
parameters can be output at the same time.
The cycle of the visualization is presettable. 1000 µs, the RT0-Cycle time
62.5 µs can be set as cycle time.

4.4.13.2 ProDrive Analog Outputs

Figure 100:
The check box "Test input on/off" has no direct reference to any parameter. When the
"Test input on/off" check box (see below) is activated, the ID number
Test signal parameter) should be entered in the parameter
in the corresponding "Source Parameter Number" box.
230
Parameter manual b maXX BM3000
Document no.: 5.12001.07
of 820
ProDrive Analog outputs
"Visu Channel 1 Source Parameter Id (Z125.1–) or
"Visu Channel 2 Source Parameter Id (Z125.2–)
Z1.8–
Z125.22–
(from the
Baumüller Nürnberg GmbH
or

Hide quick links: