Organization Of The Parameters In The Data Sets - Baumuller b maXX BM3000 Operating Manual

Parameter
Hide thumbs Also See for b maXX BM3000:
Table of Contents

Advertisement

Description of the Software Modules and Parameters

4.5.2.3 Organization of the parameters in the data sets

Within the device there are seven separate memory areas for parameters that have the
"Data Set" attribute (DS 1 to DS 7).
In addition there is a "window" which represents the current active data set (DS 0). One
of these seven data sets is always selected active. By writing to Parameter
tive Data Set Number, Data Set 1, 2, 3, 4, 5, 6 or 7 can be selected to be active, hence it
is possible to switch between the data sets. In so doing, the window moves from DS 0 to
the memory area of the activated data set.
Example: 
Data Set 3 is activated. 
The "window" for the active data set addresses Data Set 3.
Figure 127:
Basically, only data from the active data set (DS 0) can be accessed via external option
modules or Fieldbuses.
Active data set
Parameter manual b maXX BM3000
Document no.: 5.12001.07
4
Z105.6–
Ac-
363
of 820

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B maxx bm2500

Table of Contents