Parameter Overview - Baumuller b maXX BM3000 Operating Manual

Parameter
Hide thumbs Also See for b maXX BM3000:
Table of Contents

Advertisement

Description of the Software Modules and Parameters
Figure 212:
If the resulting signal complies with the sine of about two cycles, then it can be assumed
that the notch position search operates reliable with the injection.

4.8.10.5 Parameter overview

Functional block:
Parameter 19.52, refer to
Number
Name
133.1
Mode sensorless
133.2
Injection frequency 1
133.3
Injection amplitude 1
133.4
Bandpass bandwidth
133.5
Injection Kp
133.6
Injection frequency 2
133.7
Injection amplitude 2
133.9
2nd harmonic rate
133.10
2nd harmonic min.rate
133.11
Carrier current Id
133.12
Carrier current Iq
133.14
Status motor observer
133.15
Injection Tn
ProDrive - Resulting signal of the motor diagnosis
FbInjektion [133]
ZMotor–
from page 111
Type
Min
Max
UINT
0
0xffff
FLOAT
0
4000.0
FLOAT
1
400.0
FLOAT
1
500.0
FLOAT
-1.000000e+10 1.000000e+10 80
FLOAT
0
1000.0
FLOAT
1
400.0
FLOAT
0
100.0
FLOAT
0
100
FLOAT
-1.000000e+10 1.000000e+10 0
FLOAT
-1.000000e+10 1.000000e+10 0
DINT
0
10
FLOAT
0.1
1e10
Parameter manual b maXX BM3000
Default Value Unit
Factor
0
1:1
1000.0
Hz
1:1
100.0
V
1:1
50.0
Hz
1:1
1/s
1:1
250.0
Hz
1:1
280.0
V
1:1
0
%
1:1
5
%
1:1
A
1:1
A
1:1
0
1:1
4
ms
1:1
Document no.: 5.12001.07
4
X
X
X
X
X
X
X
X
X
X
X
X
X
649
of 820

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

B maxx bm2500