The division of the set values is made along the MTPA characteristic (maximum torque
per ampere). This characteristic now is determined by
is calculated as follows:
The remaining current from the total current set value is the lq current (Z171.16–).

4.4.5.2 Commissioning

In order to ensure an optimum in dynamic when operating a IPMSM, the following notes
for setting are mandatory:
154
Parameter manual b maXX BM3000
Document no.: 5.12001.07
of 820
– Using a Baumueller motor the data can be loaded from a motor data base. All set-
tings are carried out automatically with ProDrive.
– If no Baumueller motor is used, at first an autotuning (see
controller–
from page 199) must be executed to set the current controller roughly.
– The notch position must be set next.
– The field current can be limited via parameter limit magnetizing current (Z146.12–).
This is important in order to prevent the demagnetization of the motor.