4.5
Management

4.5.3.3 ProDrive Brake Management

Figure 130:

4.5.3.4 Parameter overview

Functional block:
Number
Name
134.1
Mode
134.2
Status
134.3
Control automatic
134.4
Command
134.5
Torque limit
134.6
Speed limit
134.7
Timeout check-back signal
134.8
Pulse inhibit delay
134.9
Start of motion delay
134.10
Opening delay
380
Parameter manual b maXX BM3000
Document no.: 5.12001.07
of 820
ProDrive Brake management
FbBrakeMgr [134]
Type
Min
Max
DWORD 0
0xFFFFFFFF 0x22
DWORD 0
0xFFFFFFFF 0
DWORD 0
0xFFFFFFFF 0
WORD
0
0xFFFF
FLOAT
-1.00E+06
1.00E+06
FLOAT
0
1.00E+06
UINT
0
1000
UINT
0
1000
UINT
0
1000
UINT
0
1000
Default Value Unit
Factor
1:1
1:1
1:1
0
1:1
0
Nm
1:1
90
Grad/s 1:1
1000
ms
1:1
500
ms
1:1
500
ms
1:1
0
ms
1:1
Baumüller Nürnberg GmbH