Charging System; Charging Circuit; Current Leakage Inspection - TGB BLADE 600 Service Manual

Table of Contents

Advertisement

Charging System

Charging circuit

Main Switch
Fuse 20 A
Battery

Current Leakage Inspection

Turn the main switch to OFF position, and
remove the negative cable terminal (-) from the
battery.
Connect an ammeter between the negative
cable terminal and the battery negative terminal.
Caution
● In the current leakage test, set the current
range at the largest scale, then gradually
decrease to the lower scale as the test
process goes to avoid possible damage to
the ammeter and the fuse.
●Do not turn the main switch to ON position
during test.
If the leaked current exceeds the specified value,
it may indicate a short circuit.
Allowable current leakage: Less than 1mA
Disconnect each cable one by one and take
measurement of the current of each cable to
locate the short circuit.
Blue
Black
Black/Red
16. ELECTRICAL SYSTEM
Yellow
Yellow
AC Generator
Yellow
16-5