INSPECTION
• Remove the seat set.
• Turn the ignition switch ON and measure the voltage
between the following terminals of the Roll Over
sensor connector with the connector connected.
Angle
0∘
65∘
• Turn the ignition switch OFF.
• Remove the screws, washers, nuts and roll over
sensor.
• Place roll over sensor horizontal as shown and turn
the ignition switch ON.
• The roll over sensor is normal if the power supply is
closed.
• Incline the roll over sensor approximately 65
degrees to the left or right with the ignition switch
ON.
• The roll over sensor is normal if the power supply is
open.
• If you repeat this test, first turn the ignition switch
OFF then turn the ignition switch ON.
REMOVAL / INSTALLATION
• Disconnect the roll over sensor 2P connector.
• Remove the two screws, nuts and roll over sensor.
• Installation is in the reverse order of removal.
• Tighten the mounting screws securely.
NOTE: Install the roll over sensor with its
"UP" mark facing up.