ROLL OVEWR SENSOR CIRCUIT MALFUNCTION
DETECTED CONDITION
The sensor voltage should be the following
for 2 sec. and more, after ignition switch is
turned ON.
0.2 Sensor voltage < 4.6 V
Sensor voltage is higher than specified
value.
Sensor voltage is lower than specified value.
INSPECTION
Step 1
(When output voltage is out of specified)
1) Remove the seat set.
2) Turn the ignition switch OFF.
3) Check the Roll over sensor coupler for loose
or poor contacts.
4-1. FUEL INJECTION SYSTEM
POSSIBLE CAUSE
• TO sensor circuit open or short
• TO sensor malfunction
• ECU malfunction
•TO sensor circuit open or shorted to
VSENS or ground circuit open
•TO sensor circuit shorted to ground or
VSENS circuit open