15-2. ELECTRIC POWER STEERING

EPS Unit Removal

Remove the following items:
• Both internal fender.
• The front bumper.
• Disconnect the wiring of headlamp and power
source.
• The front cover.
• The inlet tube.
Loose the handle steering lock nut.
Lift up and dismounting the steering shaft.
Torque: 280~320 kgf-cm
Disconnect the wiring on the motor.
Disconnect the wiring on the controller.
Remove the three mounting bolts ① of EPS
body.
Torque: 250~300 kgf-cm
15-2-12