Set The Number Of Days Until The First Test Report; Changing Domestic Phone Numbers; Installer Code Functions; Domestic Dialing Digits - Bosch ICP-CC408 Installation Manual

Table of Contents

Advertisement

ICP-CC408 | Installation Guide | 6.0
Table 23: Installer Code Functions
Function
Description
0
Reserved
1
Set the number of days until the first Test
Report
(Section 6.1.1)
2
Change domestic telephone numbers
(Section 6.1.2)
3
Change the telco arming/disarming
sequence
(Section 6.1.3)
4
Set STAY Mode 2 zones
(Section 6.1.4)
5
Satellite Siren (EDMSAT) Service Mode
(Section 6.1.5)
6
Turn Telephone Monitor Mode on and off
(Section 6.1.6)
7
Walk Test Mode
6.1.7
(Section
8
Event Memory Recall Mode
(Section 6.1.8)
9
Reserved
6.1.1
Set the Number of Days until the First
Test Report
This function determines when the system sends the
first Test Report (Contact ID Event Code 602). If you
do not use this Installer Code Function, the first Test
Report is sent to the base station receiver after the
repeat interval programmed in Location 366 (refer to
Section 15.21 Test Reporting Time on page 67). If you
want the system to send the first Test Report sooner
than the repeat interval, use this function to set when
the first Test Report is sent.
To set the first Test Report:
1. Enter the Installer Code and press [1][AWAY].
Three beeps sound and the STAY and AWAY
indicators flash.
2. Enter the number of days (1 to 15) until the first
Test Report is sent and press [AWAY].
Two beeps sound and the STAY and AWAY
indicators are extinguished. The system returns
to the disarmed state.
Each time you enter Installer's
Programming Mode, the first Test Report
time defaults to the repeat interval set in
Location 366.
The number of days decrements by one at
2400 hours as set in Locations 901 to
904 (refer to Section 17.15 System Time
on page 77).
Example
If the repeat interval is set to 7 days, but you want
the first Test Report to be sent in 2 days, enter:
[1 2 3 4 1][AWAY][2][AWAY]
Bosch Security Systems, Inc. | 12/08 | F01U089463-02
System Functions
)
6.1.2

Changing Domestic Phone Numbers

When the system is set up for domestic dialing, this
function allows the installer to view and program the
telephone numbers that the system calls if an alarm
occurs. Refer to Section 9.0 Domestic Dialing on page
43 for more information.
To change domestic phone numbers:
1. Enter the Installer Code and press [2][AWAY].
Three beeps sound and the STAY and AWAY
indicators flash.
If telephone numbers are programmed, they
appear one digit at a time using the remote
codepad indicators. Refer to Table 25 on page 30
for the indicators and their meanings.
If no telephone numbers are programmed, an
additional two beeps sound after entering this
mode. These two beeps normally sound after
you enter the last digit of the last phone number.
2. Enter the first phone number.
Each digit appears as you enter it.
3. If you are programming another phone number,
press [STAY][4] to separate the end of one
phone number and the beginning of the next.
If you are not programming other numbers, go
to Step 5.
4. Repeat Steps 2 and 3 to program another phone
number.
5. Press [AWAY] to exit from this mode.
Table 24: Domestic Dialing Digits
Digit
Number to
Required
Program
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
Example
If you want to program two separate telephone
numbers (9672 1777 and 9672 1233), enter:
[1 2 3 4 2][AWAY][9 6 7 2 1 7 7 7][STAY]
[4 9 6 7 2 1 2 3 3][[AWAY]
You can suspend domestic dialing at any time (for
example, you are moving house and do not want the
system to continue calling your work place or mobile
phone).
To disable domestic dialing:
Enter the Installer Code and press [2][AWAY]
[STAY][4][AWAY].
EN | 29
Digit
Number to
Required
Program
8
8
9
9
10
refer to 0
*
* 1
#
* 2
4 sec pause
* 3
break
* 4
15
* 5

Hide quick links: