When isolating 24-Hour Zones, the system
automatically sends a Zone Bypass Report when the
zone is selected to be isolated. All non-24-Hour zones
send a Bypass Report only when the system is
armed.
If you do not want the system to report Zone Bypass
Reports, program Locations 385 and 386 to 0 (refer
to Section 15.3 Zone Status – Bypass Reports on page 65).
4 – Forced Arming Allowed
If this option is selected, the system can be armed
with the zone unsealed. If this option is not selected,
the system does not allow the User Code holder to
arm the system until the zone is sealed or manually
isolated. Refer to Section 3.11 Isolating Zones on page
17 for more information.
8 – Zone Restore Report
If this option is selected, the zone sends Restore
Reports when the zone is restored. If this option is
not selected, the zone does not send Restore Reports
when the zone is restored.
If a non-24-Hour zone is not restored when the
system is disarmed, the system automatically sends a
Zone Restore Report for that zone. All 24-Hour
zones send a Zone Restore Report only when the
zone is restored.
14.3.8

Zone Report Code

If you want the control panel to transmit Zone Alarm
Reports, program this location as 1. If not, program
this location as 0.
14.3.9

Zone Dialer Options

By default, a zone reports only to Receiver 1. Table
53 on page 64 lists the reporting options for the zone.

Table 53: Zone Dialer Options

Option
Description
0
No report required
1
Receiver 1
2
Receiver 2
4
Receiver 1 and Receiver 2
8
Receiver 2 only when Receiver 1 fails
14.4

Swinger Shutdown Count for Siren

Location
379
Default
3
1 to 15
Number of times siren operates until lockout
Location 379 determines the number of times the
sirens can be activated before lockout options take
effect. This location has no effect unless you program
at least one zone for lockout siren. Refer to Section
14.3.5 Zone Options 1 on page 61 to program zones
for lockout siren.
Bosch Security Systems, Inc. | 12/08 | F01U089457-02
Zone Information
Only alarms activated from zone inputs can
decrement the Swinger Shutdown Counter. Alarms
such as Codepad Panic, Access Denied, and other
system alarms do not affect the Swinger Shutdown
Count.
When the sirens are operating, the Swinger
Shutdown Counter is decremented only by the first
zone that activated the alarm. Any other zones
activated during Siren Run Time do not affect the
counter.
When the Swinger Shutdown Count is reached, all
zones that were activated are locked out according to
their individual lockout settings.
Example
All eight zones are programmed for lockout siren
with a Swinger Shutdown Count of 3. If Zone 1
activates an alarm, the Swinger Shutdown Count is
decremented by one after the end of Siren Run Time
to a swinger shutdown count of 2.
After the Siren Run Time is reset from the previous
alarm, Zone 2 activates an alarm and activates the
sirens. After the sirens are reset, the swinger
shutdown count is decremented again to 1.
If Zone 3 also activates an alarm after the sirens are
reset from Zone 2, the Swinger Shutdown Count is
decremented to 0, which locks out all three zones
from sounding the sirens until the system is reset.
At this point, the Swinger Shutdown Count for Sirens
is reset to 3 and the process of swinger shutdown for
remaining zones begins again until all zones are
locked out.
If the ICP-CC488 Control Panel is
partitioned, the Swinger Shutdown Count
for Siren applies to both Area 1 and
Area 2.
14.5

Swinger Shutdown Count for Dialer

Location
380
Default
6
1 to 15
Number of times dialer operates until lockout
Location 380 determines the number of times the
dialer can be activated before lockout options take
effect. This location has no effect unless you program
at least one zone for lockout dialer. Refer to Section
14.3.5 Zone Options 1 on page 61 to program zones
for lockout dialer.
Only alarms activated from zone inputs can
decrement the Swinger Shutdown Counter. Alarms
such as Codepad Panic, Code Retries, and other
system alarms do not affect the Swinger Shutdown
Count.
When the dialer is online, its counter is decremented
only by the first zone that activated the alarm. Any
other zones activated while the dialer is online do not
affect the counter.