Receiver 1 - 4 Subscriber Id Number; Call Back Telephone Number; Ring Count; Access Codes - Bosch AMAX panel 2000 Installation Manual

Hide thumbs Also See for AMAX panel 2000:
Table of Contents

Advertisement

54
en | System Informations 1
7.7.5

Receiver 1 - 4 Subscriber ID Number

(Refer to Section 10.1.1 Receiver Parameters, page 78). The Subscriber ID Number is
transmitted to identify the calling control panel. Enter the Subscriber ID Number in the six
locations provided for each destination. Any Subscriber ID Number is less than 6 digits, use 0
to full fill the data in the higher bits.
Example
Program Subscriber ID Number as 4729 in six locations: [0 0 4 7 2 9]
7.7.6

Call back Telephone Number

(Refer to Section 8.6.4 A-Link Plus Software, page 73 and Section 10.3.2 Remote Programming/
Control, page 80).This location stores the telephone number to call when Upload/Download is
requested or the user enters his code + 7 and presses [#] to initiate a modem call from the
control panel to establish a communication link with the remote computer. The computer
must be running A-Link Plus RPS software and must be set to Waiting for an Incoming Call.
The Call Back Telephone Number is also necessary if remote connect with callback verification
is required(refer to7.4.3 on page 49)
7.7.7

Ring Count

(Refer to Section 10.3.1 Ring Count, page 80). This location sets the number of rings before
the control panel answers an incoming call. Setting this count to an acceptable level has an
effect only if Remote Arming and the Remote Upload/Download are enabled. Programming
this location to 0 prevents the control panel from answering incoming calls regardless of any
other programmed options.
7.8

Access Codes

This section describes the access codes used to assign privileges and access functions for
User Code holders of the system. There are two types of access codes, the Installer Code and
User Codes. Each of these codes allows specific access and operation of control panel
functions.
7.8.1

Installer Code

(Refer to Section 10.6.1 Installer code, page 87). The Installer Code can be up to four digits
long. When the system is in disarmed status and no active alarm, it will access to Installer's
Programming Mode.
Installer Code functions allow the installer to execute functions when the system is disarmed.
Refer to Section 6 System Functions, page 39 for more information.Refer to
Section 3.3.1 Programming with the AMAX Keypad 2000, page 14 for more information on
system programming.
The installer code works only if its enabled by a user code holder.
7.8.2

AMAX panel 2000 / AMAX panel 2000 EN User Codes

(Refer to Section 10.6.2 User Codes, page 87.) The AMAX panel 2000/AMAX panel 2000 EN
Control Panel can have up to sixteen programmable User Codes (1 - 16) to operate the
system. You can program User Code 1-8 as keypad user codes and 9-16 as hand-held remote
radio keyfob user codes.
To remotely operate the system by hand-held keyfob, program User code 9 – 16 as remote
user code.
F.01U.241.127 | V4 | 2011.12
Installation Manual
AMAX panel 2000 / AMAX panel 2000 EN
Bosch Sicherheitssysteme GmbH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Amax panel 2000 en

Table of Contents