Use Program 51-05 : NetLink Timer Settings to set the various timers in the NetLink
system.
Item
No.
01
02
03
04
05
06
07
SV8100 Programming Manual
Item
Keep Alive Sending Interval
Set the Keep Alive sending interval time from the
Secondary system to confirm communication
with the Primary system.
Keep Alive Response Waiting Time
Set the time the Secondary system waits for a
response from the Primary system before cutting
off communication.
Primary Search Packet Sending Interval
While searching the Primary system, the system
sends a packet at this interval.
Primary Search Time Maximum Value
Total Primary system seek time.
Top Priority Primary Detection Packet
Sending Interval
When current Primary system is not Top Priority
Primary System, the system sends packet to
check if Top Priority System exists.
Primary Compulsion Specification Trial
Maximum Time
When the forced change Primary command is
executed, the system searches the new Primary
system for this time.
Socket Refresh Time
If the IP connection becomes unstable, the
keep-alive function does not work. If there is no
data traffic for this time, the socket is refreshed.
Program 51 : NetLink Service

51-05 : NetLink Timer Settings

Input Data
1~3600 (sec)
0, 5~10800 (sec)
(0 = infinity)
1~3600 (sec)
5~10800 (sec)
1~3600 (sec)
1~10800 (sec)
20~3600 (sec)
Issue 11.0
Default
5
20
5
20
10
30
40