Issue 11.0
Item
71
72
73
74
75
76
77
78
79
80
81
82
Feature Cross Reference
None
2 - 696
Name
Guard Time 1 (Ground)
Guard Time 1 (DID)
Guard Time 1 (E&M)
Guard Time 1 (OPX)
Guard Time 2 (ALL)
Dial Sending Complete Time
(ALL)
ON-HOOK bit Send Time (ALL)
Open Loop Time (Loop)
Open Loop Time (Ground)
Open Loop Time (DID)
Open Loop Time (E&M)
Open Loop Time (OPX)
Conditions
None
Input Data
1~255
(100ms ~ 25500ms)
1~250
(4ms ~ 1000ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~250
(4ms ~ 1000ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~250
(4ms ~ 1000ms)
1~250
(4ms ~ 1000ms)
1~250
(4ms ~ 1000ms)
Program 81 : Basic Hardware Setup for Trunk
UNIVERGE SV8100
Default
9
900ms
3
12ms
20
2000ms
40
4000ms
6
24ms
6
600ms
6
600ms
6
600ms
6
600ms
13
52ms
13
52ms
13
52ms