Program 81 : Basic Hardware Setup for Trunk
Level:
IN
Description
Use
option data type.
Input Data
Feature Cross Reference
None
SV8100 Programming Manual

81-17 : CODEC Filter Option Data Type Setup

Program 81-17 : CODEC Filter Option Data Type Setup
Line Type
Item
Item
No.
01
Option Type
0 = None
1 = Type 5: 600Ω Line loss 2dB
2 = Type 6: China standard (200Ω+(100nF//680Ω))
3 = Type7: China seimence tel (160Ω+(150nF//1100Ω))
4 = Type 8: Brazil 900Ω
5 = Type 9: 600Ω Line loss 10dB
6 = Type 10: Reserved
7 = Type 11: Reserved
8 = Type 12: Reserved
9 = Type 13: Reserved
10 = Type 14: Reserved
11 = Type 15: for test
Conditions
None
to define the CODEC filter
1:COIU/082U(COIDB)/002U(COIDB)
2:DIOPU(LD Trunk)
3:TLIU(2W)
4:TLIU(4W)
Input Data
Issue 11.0
Default
0