UNIVERGE SV8100
Item
No.
14
16
17
18
19
20
21
23
Feature Cross Reference
None
SV8100 Programming Manual
Item
Loop Start/Ground Start
--- Not Used ---
Sync. Ringing
Specify whether or not CO/PBX calls
follow Synchronous Ringing.
Synchronous Ringing does not
apply to incoming DID calls,
off-hook ringing calls, or CO/
PBX ring transfer calls.
Busy Tone Detection on Talking
Busy Tone Detection Frequency
Busy Tone Detection Interval
Fax Branch Connection
Caller ID Receiving Method
Rings extension before receiving
Caller ID (1) or after receiving Caller ID
(0).
Conditions
None
Input Data
0 = Loop Start (Loop)
1 = Ground Start
(Ground)
0 = Disable
1 = Enable
0 = Disable
1 = Enable
1~255
0 = No
1 = Yes
0 = No
1 = Yes
0 = Wait Caller ID
1 = Immediate Ring
Issue 11.0
Related
Default
Program
0
1
0
1
14-02-18
0
14-10
0
1
2 - 155