NEC UNIVERGE SV8100 Programming Manual page 886

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue 11.0
Alarm
Type
Report
No.
40
0
0
CS error noti-
fication 2.
41~49
--- Reserved ---
50
1
0
System Start
Notification
51
0
0
System Data
change
52
0
0
VRS/InMail
CF available
space
53
0
0
--- Reserved ---
54
2
0
License
Management
Table Full
55
2
0
Regular
maintenance
exchange
notification.
56
--- Reserved ---
2 - 844
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
CS detected the factor that
the noise is generated
between CS-PS, BBIC
reset was executed, and it
was restored automatically.
The system started.
CD-CP00-US Upgrade is
performed or Programming
change is made.
Provide alarm when the
available space on the
VRS/InMail CF card is
getting below threshold.
A new TCP/IP terminal and
the DSP board were not
able to be added to the
application license
management table.
• The license management
table is registering full.
The regular maintenance
exchange day has passed.
Cause
Action
1. Outgoing noise.
Confirm the following
2. Method of setting
when it happens
up CS.
frequently during
3. Wiring to
operation.
connect CSIU
1. Confirm CS is
unit with CS.
normally connected.
4. Hard defect of
2. Confirm the wiring
CS.
between CSIU-CS is
5. Hard defect of
normal.
CSIU.
3. Exchange CS.
4. Exchange CSIU.
The system was
No action needed.
started.
No action needed.
0 = Not Set, no
Have users remove
alarm provided
stored messages, or if
needed, use InMail
1 = Major, when the
Utility to reinitialize CF
avail. space gets
back to factory default.
below 3%
2 = Minor, when
the avail. space
gets below 10%
Maximum 512
Delete license
license information
information on an
on the TCP/IP
unnecessary TCP/IP
terminal is
terminal with PRG
registered, and a
90-44.
new terminal
cannot be
registered.
• The regular
Do the maintenance
maintenance
exchanges of pertinent
exchange day
parts, and set the next
that had been set
regular maintenance
with PRG 90-51
exchange day with
exceeded it.
PRG 90-51.
Program 90 : Maintenance Program
UNIVERGE SV8100
Alarm
Recovery
Status
This error has
ERR
been
REC
recovered
when it is
notified.
This error can
be recovered
when avail.
space on
VRS/InMail
CF is back
above 3% or
10%,
depending on
alarm level
setting.
WAR
The excess
ERR
REC
on the regular
maintenance
exchange day
is canceled by
changing
PRG 90-51 or
when the
function is
invalidated,
the error is
recovered.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents