Description
Use Program 16-01 : Department Group Basic Data Setup to set the
function mode for each department group. There are 64 available Department
Groups.
Input Data
Item
No.
01
02
03
SV8100 Programming Manual

Program 16 : Department Group Setup

16-01 : Department Group Basic Data Setup

Department Group Number
Item
Department Name
Department Calling Cycle
Set the call routing for
Department Calling. Routing
can be either circular (cycles to
all phones in group) or priority
(cycles to highest priority
extensions first).
Department Routing when
Busy (Auto Step Call)
Set how the system routes an
Intercom call to a busy
Department Group member.
Intercom callers to the
extension can either hear busy
or route to the first available
department number. This only
occurs for calls to the extension
directly, not the department
number assigned in Program
11-07.
1~64
Input Data
Default
Maximum 12 characters
0 = Normal Routing
(Priority)
1 = Easy – UCD Routing
(Circular)
0 = Normal (Intercom
caller to busy
department member
hears busy)
1 = Circular (Intercom
callers to busy
department member
routes to idle
member)
Program
16
Related
Program
No
11-07
setting
0
16-02
0
16-02
2 - 223