Program 32 : Door Box and Sensor Setup

Level:
IN
Description
Use Program 32-01 : Door Box Timers Setup to assign the timers used for
the Door Box.
Input Data
Item
No.
01
02
03
Conditions
None
Feature Cross Reference
SV8100 Programming Manual
The Door Box feature is called Door Phone when programming via
WebPro and using a multiline terminal.
Item
Door Box Answer Time
A multiline terminal user must answer Door Box chimes
during this time.
Door Lock Cancel Time
When a single line (2500 type) telephone user hook
flashes or a multiline terminal user presses the Recall key
while talking to a Door Box, the strike stays open for this
time.
Off-Premise Call Forward by Door Box Disconnect
Timer
Define the conversation period for an Off-Premise Call
Forward by Door Box call. When this timer expires, the
caller hears busy tone for three seconds (fixed time), and
the call is then disconnected.
Door Box

32-01 : Door Box Timers Setup

Input Data
0~64800
0~64800
0~64800
Program
32
Default
30
(sec)
10
(sec)
60
(sec)