Ip Telephone Terminal Basic Data Setup - NEC UNIVERGE SV8100 Programming Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Issue 11.0
Level:
IN
Description
Use Program 15-05 : IP Telephone Terminal Basic Data Setup to set up the basic
settings for an IP telephone.
Input Data
Item
Item
No.
01
Terminal Type
02
IP Phone Fixed
Port
Assignment
04
Nickname
07
Using IP
Address
15
CODEC Type
2 - 184
Program 15 : Extension, Basic Setup

15-05 : IP Telephone Terminal Basic Data Setup

Extension Number
Input Data
0
= NGT
1
= H.323
2
= SIP
3
= MEGACO
4
= SIP-MLT
MAC address
00-00-00-00-00-00 to
FF-FF-FF-FF-FF-FF
Up to 48 characters
0.0.0.0~255.255.255.255
1-Type 1
2-Type 2
3-Type 3
4-Type 4
5-Type 5
Default
0
Viewing Only – No changes
permitted
00-00-00-00-00-00
MAC Address of registered
SIP MLT phone is stored
and/or can input the MAC
address of an SIP MLT
phone so when it comes
online it is provided with the
extension in which the MAC
address matches.
No setting
Nickname section on Invite
message. Example:
Extension 100 has a
Nickname set to PAUL.
Extension 101 has
command 15-05-17 set to
Nickname. The inbound call
to extension 101, from 100,
shows PAUL.
0.0.0.0
Informational Only
registered IP Phones
1
Assign the CODEC Type of
the MLT SIP.
Program 15 : Extension, Basic Setup
UNIVERGE SV8100
Maximum eight digits
Related
Description
Program
15-05-01
15-05-17
15-05-01
84-24-XX

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents