Program 81 : Basic Hardware Setup for Trunk
81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup
Level:
IN
Description
Use Program 81-06 : ISDN BRI & PRI Layer 3 (T-Point) Timer Setup to define the
various basic timers for layer 3 of ISDN BRI/PRI (defined in Program 10-03-04).
Input Data
Item
No.
SV8100 Programming Manual
Layer 3 Timer Type Number
Item
01
T301
Specify the timer value started when
the ALERT message is received.
02
T302
Specify the timer value started when
the SETUP ACK is sent. Timer is also
restarted when INFO is received.
03
T303
Specify the timer value started when
SETUP is sent.
04
T304
Specify the timer value started when
the SETUP ACK is received. Timer is
also restarted when INFO is received.
05
T305
Specify the timer value started when
DISC without progress No. 8 is sent.
06
T306
Specify the timer value started when
DISC with progress indicator No. 8 is
sent. This timer is valid for Network
side use only.
07
T307
Specify the timer value started when
SUSPEND ACK is sent. This timer is
valid for Network side use only.
08
T308
Specifies the timer value started when
REL is sent.
09
T309
Specify the timer value started at data
link disconnection.
10
T310
Specify the timer value started when
CALL PROC is sent.
11
T312
Specify the timer value started when
SETUP is sent or re-sent on
broadcast data link. This timer is valid
only for Network side use only.
Description
1~5
Input Data
0,180~254 (sec)
1~254 (sec)
1~254 (sec)
0~254 (sec).
1~254 (sec)
0~254 (sec)
1~254 (sec)
1~254 (sec)
1-254 (sec)
0~180 (sec)
1~254 (sec)
Issue 11.0
Default
180
15
4
30
30
30
180
4
90
180
6
2 - 689