Alarm
Type
Report
No.
13
0
0
Charge
Management
Link Error
14
0
0
LAN Link
Error
15
0
0
Network Keep
Alive
16
0
0
SMDR Link
17
1
0
Denial of
service
18~28
--- Reserved ---
29
0
0
Charge
Management
Buffer full
30
2
0
SMDR Buffer
full
31
1
0
Auto Dial after
Sensor
Detection
2 - 842
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
The link with the charge
management device came
off.
The link with LAN on
CD-CP00-US came off.
1. The network connection
has been cut.
2. Network Keep Alive
restoration.
3. Response notification on
network Keep Alive.
The system received an
illegal packet.
The temporary buffer for
the charge management in
main device overflowed,
and a part of unoutput
charge data disappeared
because it could not output
the charge management
data.
The temporary buffer for
SMDR in main device
overflowed, and a part of
unoutput SMDR data
disappeared because it
could not output SMDR
data.
Auto dialing occurs after
sensor detection.
Cause
Action
1. Wiring problem
1. Confirm that there is
in connecting
no problem in wiring
main device with
to connect a main
charge
device with the
management
charge management
device.
device. (Whether
2. PC Problem.
ping passes for LAN
connection is
confirmed.)
2. Restart the charge
management
software.
3. Reboot PC, and start
charge management
software.
1. LAN cable
Confirm the operation
defective.
of LAN connector, LAN
2. Connected HUB
cable, and HUB again.
broken.
3. Defective
CD-CP00-US.
1. LAN cable is
1. Confirm that the
defective.
defect is on the
2. Net side trouble.
Network side.
3. Packet blocked
2. Confirm the settings
by firewall.
of HUB and the
4. Repetition of IP
router, etc.
address.
Service outage
Confirm that the defect
(DOS
is on the Network side.
1. The charge data
1. Print and delete the
is printed and
charge data at the
not deleted at
simple charge
the simple
management.
charge
2. Connect the charge
management.
management
2. The charge data
software for the
is not output to
charge management
PC for the
software and output
charge
the charge data.
management
software.
1. Problem of
1. Confirm whether
wiring to
there is problem in
connect main
wiring to connect a
device with PC.
main device with
2. PC Problem.
PC.
2. Execute the
reactivation of PC.
Sensor detect an
No action needed.
abnormality and
makes an
emergency call.
Program 90 : Maintenance Program
UNIVERGE SV8100
Alarm
Recovery
Status
When the
ERR
connection
REC
returns
normally, the
error is
recovered.
When the
ERR
connection
REC
returns
normally, the
error is
recovered.
When the
ERR
connection
REC
returns
WAR
normally, the
error is
recovered.
WAR
When the
ERR
output is
REC
restarted, the
error is
recovered.
However, the
charge
management
data after the
error occurs is
not recorded.
When the
ERR
output is
REC
restarted, the
error is
recovered.
However, the
SMDR data
after the error
occurs is not
recorded.

Hide quick links: