UNIVERGE SV8100
Item
52
53
54
55
56
57
58
59
60
61
62
63
64
65
66
67
68
69
70
SV8100 Programming Manual
Name
Receive HookFlash Duration
Min. Time (E&M)
Receive HookFlash Duration
Max. Time (E&M)
Receive HookFlash Duration
Min. Time (OPX)
Receive HookFlash Duration
Max. Time (OPX)
Loop Off Guard Time (Loop)
Loop Off Guard Time (Ground)
Loop Off Guard Time (DID)
Loop Off Guard Time (E&M)
Loop Off Guard Time (OPX)
Double Ringing Send Time 1
(OPX)
Double Between Ringing Send
Time 1 (OPX)
Double Ringing Send Time 2
(OPX)
Double Between Ringing Send
Time 2 (OPX)
Single Ringing Send Time (OPX)
Receive DP Make Max. Time
(ALL)
Receive DP Break Min. Time
(ALL)
Receive DP Break Max. Time
ALL)
Single Between Ringing Send
Time (OPX)
Guard Time 1 (Loop)
Input Data
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
1~255
(100ms ~ 25500ms)
Issue 11.0
Default
3
300ms
6
600ms
3
300ms
6
600ms
20
2000ms
20
2000ms
20
2000ms
20
2000ms
20
2000ms
5
500ms
5
500ms
25
2500ms
30
3000ms
10
1000ms
9
900ms
9
900ms
9
900ms
9
900ms
9
900ms
2 - 695