Netlink Timer Settings - NEC Univerge SV8100 Programming Manual

Hide thumbs Also See for Univerge SV8100:
Table of Contents

Advertisement

Issue 1.0
Level:
IN
Description
Use Program 51-05 : NetLink Timer Settings to set the various timers within the
NetLink system.
Item
No.
01
02
03
04
05
06
07
2 - 568
Item
Keep Alive Sending Interval
This is the Keep Alive timer sending interval
from the Secondary system to confirm
communication with the Primary system.
Keep Alive Response Waiting Time
This is the time interval the Secondary system
waits for a response from the Primary system
before cutting off communication.
Primary Search Packet Sending Interval
While searching the Primary system, the system
sends a packet at this interval.
Primary Search Time Maximum Value
Total time of Primary system seek time.
Top Priority Primary Detection Packet
Sending Interval
When current Primary system is not Top Priority
Primary System, the system sends packet to
check if Top Priority System exists.
Primary Compulsion Specification Trial
Maximum Time
When the forced change Primary command is
executed, the system will search the new
Primary system for this amount of time.
Socket Refresh Time
For some reason, the IP connection may
become unstable. Then keep-alive function does
not work. To avoid this, if there is no data traffic
for this time, the socket is refreshed.
Program 51 : NetLink Service

51-05 : NetLink Timer Settings

Input Data
1~3600
0, 5~10800
(0 = infinity)
1~3600
5~10800
1~3600
1~10800
20~3600
Program 51 : NetLink Service
UNIVERGE SV8100
Default
5
0
5
20
10
30
40

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents