NEC UNIVERGE SV8100 Programming Manual page 883

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

UNIVERGE SV8100
Alarm
Type
Report
No.
6
0
0
Blocking
7
1
0
Power failure
8
1
0
RAM Backup
Battery Error
9
--- Reserved ---
10
0
0
ISDN Link
Error
11
0
0
CTI Link Error
12
0
0
ACD MIS Link
Error
SV8100 Programming Manual
Table 2-20 Description of Alarm (Continued)
Name
Content of Alarm
The link of terminals
connected with the ESI
package came off.
The supply of the
commercial power
stopped.
RAM backup battery on the
CD-CP00-US blade is
unplugged or defective.
Layer1 link of ISDN lines
came off.
The link with the CTI server
came off.
The link with ACD MIS
client PC came off.
Cause
Action
1. Terminal
1. Confirm the terminal
breakdown.
connected with
2 Faulty wiring and
same ESI. If they
wiring
work normally,
termination.
confirm the
3. External noise.
breakdown or the
4. ESI package
wiring for the
Breakdown.
terminal.
2. Exchange the
terminal that doesn't
work and the
working terminal,
and confirm it's
working. An external
factor of the noise
etc. is thought.
3. Confirm wiring and
the installation,etc.
4.Check with
manufacturer if the
problem occurs
again.
1. The power cable
1. Confirm the power
came off.
supply outlet when
2. Power failure
the commercial
3. The power
power has not
supply broke
stopped.
down.
2. Check with the
manufacturer if the
problem occurs
again.
Check the battery
connector. If it is
connected correctly,
replace the battery.
1. Check
1. Confirm the data of
connection
PRG10-03.
between main
2. Confirm wiring and
device and ISDN
installation of DSU.
line.
3. Check with the
2. DSU breakdown
manufacturer if the
3. The setting of
problem occurs
PRG10-03 does
again.
not correspond
to an actual line.
1. LAN cable
1. Confirm the CTI
defective.
server, wiring, and
2. Connected HUB
the connection.
broken.
2. Check with
3. The CTI server
manufacturer if the
doesn't start
problem occurs
normally.
again.
1. LAN cable
1. Confirm ACD MIS
defective.
client PC and
2. Connected HUB
connected part.
broken.
2. Check with
3. The CTI server
manufacturer if the
doesn't start
problem occurs
normally.
again.
Issue 11.0
Alarm
Recovery
Status
The error is
ERR
recovered
REC
when
connecting or
exchanging it.
When the
ERR
commercial
REC
power is
restored, the
error is
recovered.
The error is
ERR
recovered
REC
once the
battery is
replaced.
When the
ERR
connection
REC
returns
normally, the
error is
recovered.
When the
ERR
connection
REC
returns
normally, the
error is
recovered.
When the
ERR
connection
REC
returns
normally, the
error is
recovered.
2 - 841