Program 14 : Trunk, Basic Setup; Basic Trunk Data Setup - NEC UNIVERGE SV8100 Programming Manual

Hide thumbs Also See for UNIVERGE SV8100:
Table of Contents

Advertisement

Level:
IN
Description
Use Program 14-01 : Basic Trunk Data Setup to set the basic options for
each trunk port. Refer to the table below for a description of each option, its
range and default setting.
Input Data
Item
No.
01
02
03
SV8100 Programming Manual

Program 14 : Trunk, Basic Setup

Trunk Port Number
Item
Input Data
Trunk Name
Up to 12
Characters
Set the names for
trunks. The trunk
name displays on a
multiline terminal for
incoming and
outgoing calls.
Transmit Level
1~63
(-15.5dB~
Select the CODEC
gain for the trunk. The
+15.5dB in 0.5dB
option sets the gain
intervals)
(signal amplification)
for the trunk you are
programming.
Receive Level
1~63
(-15.5dB ~
Select the CODEC
+15.5dB in 0.5dB
gain for the trunk. The
intervals)
option sets the gain
(signal amplification)
for the trunk you are
programming.

14-01 : Basic Trunk Data Setup

001~200
Default
Line 001
Line 002
Line 003
:
Line 200
32 (0dB)
32 (0dB)
Program
14
Related
Program
2 - 145