Use Program 90-10 : System Alarm Setup to assign a status to system alarms. You
can designate an alarm as Major or Minor. This program also assigns whether or not
the alarm information is reported to the predefined destination.
Input Data
Alarm
Type
Report
No.
1
2
0
PKG Initialize
Error.
2
2
0
PKG
Mounting
Error
SV8100 Programming Manual
Program 90 : Maintenance Program
Alarm Number
Item
No.
01
02
Table 2-20 Description of Alarm
Name
Content of Alarm
1. The PKG failed to
initialize.
2. The PKG did not start
normally.
The unit did not step on a
regular procedure and it
was pulled out. Or, it is not
normally inserted.

90-10 : System Alarm Setup

Item
Input Data
0 = Not Set
Alarm Type
1 = Major Alarm
2 = Minor Alarm
Report
0 = Not Report (No autodial)
1 = Report (autodial)
Cause
1. PKG not inserted
firmly.
2. PKG was
removed, but not
reinserted firmly.
3. Old PKG data
still reported due
to no
initialization.
1. The package is
not completely
inserted.
2. The package is
out of order.
001~100
Action
Recovery
1. Insert PKG firmly.
During
initialization,
2. Insert PKG firmly.
the PKG is
3. Delete slot
recognized.
information in
PRG 90-05 and
insert the PKG
again.
1. Insert the package
When unit is
firmly.
reconfirmed,
2. Try again after
the error is
initializing the
recovered.
system data once
when LED doesn't
blink normally.
3. Exchange packages.