Program 82 : Basic Hardware Setup for Extension
Level:
IN
Description
Use Program 82-12 : OPX Initial Data Setup to define the various initial data for
OPX packages.
Input Data
Item
Item
No.
01
Bounce Protect Time
02
HookFlash Start Time
03
HookFlash End Time
Feature Cross Reference
None
2 - 730
Description
Specify a time for detection of a valid
off-Hook indication that is long enough
to prevent an unintentional bounce of
the receiver from being detected as a
new Off-Hook indication from a single
line telephone.
Specify the minimum hookflash time
from a single line telephone or analog
Voice Mail system before it is detected
as the beginning of a valid hookflash.
Specify the maximum hookflash
duration from a single line telephone to
receive a second dial tone.
Conditions
None

82-12 : OPX Initial Data Setup

Input
0 = No Setting
1~15 = 100ms~1.5sec
0 = 40ms
1~15 = 90ms~790ms
0 = HST+0ms
1~15=HST+100ms~HST+1500
ms (HST=Hookflash Start Time)
Program 82 : Basic Hardware Setup for Extension
UNIVERGE SV8100
Default
3
(300ms)
5
(450ms)
7
(700ms)