| Congestion Control
C
9
HAPTER

Automatic Traffic Control

A
T
UTOMATIC
RAFFIC
C
ONTROL
Use the Traffic > Congestion Control > Auto Traffic Control pages to
configure bounding thresholds for broadcast and multicast storms which
can automatically trigger rate limits or shut down a port.
CLI R
EFERENCES
"Automatic Traffic Control Commands" on page 773
C
U
OMMAND
SAGE
ATC includes storm control for broadcast or multicast traffic. The control
response for either of these traffic types is the same, as shown in the
following diagrams.
Figure 109: Storm Control by Limiting the Traffic Rate
Storm Alarm
Storm Alarm
Traffic
Traffic
Fire TRAP
Fire TRAP
[kpps]
[kpps]
StromAlarm
StromAlarm
Alarm Fire
Alarm Fire
ClearTRAP
ClearTRAP
Threshold
Threshold
(1~255kpps )
(1~255kpps )
AlarmClear
AlarmClear
Threshold
Threshold
(1~255kpps )
(1~255kpps )
The key elements of this diagram are described below:
Alarm Fire Threshold – The highest acceptable traffic rate. When
ingress traffic exceeds the threshold, ATC sends a Storm Alarm Fire
Trap and logs it.
When traffic exceeds the alarm fire threshold and the apply timer
expires, a traffic control response is applied, and a Traffic Control Apply
Trap is sent and logged.
Alarm Clear Threshold – The lower threshold beneath which a control
response can be automatically terminated after the release timer
expires. When ingress traffic falls below this threshold, ATC sends a
Storm Alarm Clear Trap and logs it.
When traffic falls below the alarm clear threshold after the release
timer expires, traffic control (for rate limiting) will be stopped and a
Traffic Control Release Trap sent and logged. Note that if the control
action has shut down a port, it can only be manually re-enabled using
Manual Control Release (see
– 232 –
TrafficControl
TrafficControl
Apply Trap
Apply Trap
Storm Alarm
Storm Alarm
Fire TRAP
Fire TRAP
Apply Timer
Apply Timer
expired
expired
Auto Storm Control
Auto Storm Control
(0~300sec)
(0~300sec)
page
235).
Traffic without storm control
Traffic without storm control
Traffic with storm control
Traffic with storm control
StromAlarm
StromAlarm
ClearTRAP
ClearTRAP
TrafficControl
TrafficControl
Release Trap
Release Trap
Release Timer
Release Timer
expired
expired
(0~300sec)
(0~300sec)
Time
Time