Edge-Core ECS3510-26P Management Manual page 53

26-port fast ethernet layer 2 switch
Hide thumbs Also See for ECS3510-26P:
Table of Contents

Advertisement

A
C
CCESS
ONTROL
L
ISTS
P
C
ORT
ONFIGURATION
R
L
ATE
IMITING
P
M
ORT
IRRORING
P
T
ORT
RUNKING
S
C
TORM
ONTROL
Other authentication options include HTTPS for secure management access
via the web, SSH for secure management access over a Telnet-equivalent
connection, SNMP Version 3, IP address filtering for SNMP/Telnet/web
management access. MAC address filtering and IP source guard also
provide authentication for port access. While DHCP snooping is provided to
prevent malicious attacks from insecure ports.
ACLs provide packet filtering for IP frames (based on address, protocol,
TCP/UDP port number or TCP control code) or any frames (based on MAC
address or Ethernet type). ACLs can be used to improve performance by
blocking unnecessary network traffic or to implement security controls by
restricting access to specific network resources or protocols.
You can manually configure the speed, duplex mode, and flow control used
on specific ports, or use auto-negotiation to detect the connection settings
used by the attached device. Use full-duplex mode on ports whenever
possible to double the throughput of switch connections. Flow control
should also be enabled to control network traffic during periods of
congestion and prevent the loss of packets when port buffer thresholds are
exceeded. The switch supports flow control based on the IEEE 802.3x
standard (now incorporated in IEEE 802.3-2002).
This feature controls the maximum rate for traffic transmitted or received
on an interface. Rate limiting is configured on interfaces at the edge of a
network to limit traffic into or out of the network. Packets that exceed the
acceptable amount of traffic are dropped.
The switch can unobtrusively mirror traffic from any port to a monitor port.
You can then attach a protocol analyzer or RMON probe to this port to
perform traffic analysis and verify connection integrity.
Ports can be combined into an aggregate connection. Trunks can be
manually set up or dynamically configured using Link Aggregation Control
Protocol (LACP – IEEE 802.3-2005). The additional ports dramatically
increase the throughput across any connection, and provide redundancy by
taking over the load if a port in the trunk should fail. The switch supports
up to 12 trunks.
Broadcast, multicast and unknown unicast storm suppression prevents
traffic from overwhelming the network.When enabled on a port, the level of
broadcast traffic passing through the port is restricted. If broadcast traffic
rises above a pre-defined threshold, it will be throttled until the level falls
back beneath the threshold.