Figure 187: Mx960 Ac Power Input Mode Switch - Juniper MX960 Hardware Manual

3d universal edge router
Hide thumbs Also See for MX960:
Table of Contents

Advertisement

Copyright © 2017, Juniper Networks, Inc.
Each High Capacity AC or DC power supply accepts two AC or DC feeds in two unique
AC or DC receptacles. It is possible to operate with one feed, but there is a reduction in
the power supply output. The DIP switch must be set according to the number of AC or
DC feeds that are present for the power supply.

Figure 187: MX960 AC Power Input Mode Switch

1
0
Position –
indicates that only one AC or DC feed is provided.
0
Position –
1
indicates that two AC or DC feeds are provided.
To check the DIP switch position:
Issue the
show chassis power
1.
connected. The following example shows there are two AC input feeds connected
for PEM 0 and one AC input feed connected for PEM 1. This indicates that the DIP
switch for PEM 0 is in position 1 and the DIP switch for PEM 1 is in position 0. These
are the proper settings.
# run show chassis power
PEM 0:
State: Online
AC input: OK (2 feed expected, 2 feed connected)
Capacity: 4100 W (maximum 4100 W)
DC output: 855 W (zone 0, 15 A at 57 V, 20% of capacity)
PEM 1:
State: Online
AC input: OK (1 feed expected, 1 feed connected)
Capacity: 1700 W (maximum 4100 W)
DC output: 969 W (zone 1, 17 A at 57 V, 57% of capacity)
Issue the
2.
show chassis alarms
DIP switch:
> show chassis alarms
Chapter 31: Troubleshooting Components
command and check to see how many feeds are
command to see if there are any active alarms on the
501

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mx960 3d

Table of Contents