Copyright © 2017, Juniper Networks, Inc.
may increase that loss, as it does not consider any redundancy or graceful
switchover strategies that you may have configured on the system.
Upgrade the MPC in slot 1 by running the
3.
command.
fpc slot 1
Verify that the MPC is upgraded by issuing the
4.
command:
info
user@host> request chassis fabric upgrade-bandwidth info
Slot State
0 Upgrade not supported
1 Upgraded
2 Empty
Verify the state of fabric planes for all MPCs by issuing the
5.
command.
user@host> show chassis fabric summary
Plane State Uptime
0 Spare 21 seconds
1 Spare 12 seconds
2 Online
12 minutes
3 Online
12 minutes
4 Online
30 minutes
5 Online
30 minutes
Verify the state of MPCs by issuing the
6.
user@host> show chassis fabric fpcs
FPC 1
PFE #0
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #1
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #2
Plane 0: Links ok
Plane 1: Links ok
Plane 2: Plane enabled
Plane 3: Plane enabled
Plane 4: Plane enabled
Plane 5: Plane enabled
PFE #3
Plane 0: Links ok
Chapter 27: Replacing Switch Fabric Components
request chassis fabric upgrade-bandwidth
request chassis fabric upgrade-bandwidth
show chassis fabric summary
command.
show chassis fabric fpcs
421