Copyright © 2017, Juniper Networks, Inc.
Verify that the fabric plane is offline by issuing the
8.
command.
user@host> show chassis fabric summary
Plane State Uptime
1 Offline
2 Online
3 minutes, 25 seconds
Verify that the State of Plane 1 is Offline.
Take the next fabric plane offline by issuing the
9.
command and verify that the fabric plane is offline by issuing the command given in
Step 2.
Take the SCB in slot 0 offline by issuing the
10.
Verify that the control board is offline by issuing the
11.
command:
user@host> show chassis environment cb 0
CB 0 status:
State
Offline
Power 1
Disabled
Power 2
Disabled
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
12.
the strap to one of the ESD points on the chassis.
Remove and replace the offline SCB on the router with the SCBE.
13.
Verify that the installation is successful and the SCB is online by issuing the
14.
chassis environment cb 0
user@host> show chassis environment cb 0
CB 0 status
State
Online
Temperature 30 degrees C / 86 degrees F
Other details, such as power, are also displayed, along with the state.
Verify that the fabric planes 0 and 1 come online correctly by issuing the
15.
fabric summary
command:
user@host> show chassis fabric summary
Plane State Uptime
0 Online 2 minutes, 9 seconds
1 Online 2 minutes, 2 seconds
Verify that the backup Routing Engine is back online by issuing the
16.
routing-engine 0
command:
user@host> show chassis routing-engine 0
Chapter 27: Replacing Switch Fabric Components
show chassis fabric summary
request chassis fabric plane offline 0
request chassis cb offline slot 0
command:
command.
show chassis environment cb 0
show
show chassis
show chassis
419